Resistance to external blows. Round-the-clock method.
Test methods
A sample (pipe) is subjected to impacts from a hammer with a set weight and shape, from a known height. The result is expressed as TIR (number of failures divided by the number of blows, expressed as a percentage as if the entire batch had been tested).
Products to test
Plastic piping systems for civil works for water of unplasticized Poly (vinyl chloride) (PVC-U) for:
Water supply and for buried and above-ground drainage and sewerage under pressure EN ISO 1452-1, -2, -3, -5.
Buried drainage and sewage without pressure EN 1401-1
Buried drainage and sewage without pressure (structured wall) EN 13476-1, -2, -3.
Plastics piping systems for civil works for water in:
Buried drainage and sewage without pressure (structured wall) made of Polyethylene (PE) EN 13476-1, -2, -3.
Buried drainage and sewage without pressure (structured wall) made of Polypropylene (PE) EN 13476-1, -2, -3.
Conveyance of water under pressure made of oriented unplasticized Poly (vinyl chloride) (PVC-O) ISO 16422
Supply of buried and above ground drainage, sewerage and irrigation water under pressure - Oriented unplasticized poly(vinyl chloride) (PVC-O) UNE EN 17176-2, -5 / UNE-CEN/TS 17176-3.
Plastic piping systems for hot and cold water installations inside buildings made of Poly (vinyl chloride) (PVC-C) EN ISO 15877-1, -2, -3, -5
Plastics piping systems for building and discharge of waste water made of:
Unplasticized poly (vinyl chloride) (PVC-U) EN 1329-1.
Unplasticized poly (vinyl chloride) (PVC-U) (structured wall) EN 1453-1
Polypropylene (PP) EN 1451-1